Intrarectal Foley catheter-assisted high-intensity focused ultrasound ablation for benign uterine diseases beyond the treatment region

作者全名:"Liu, Wei; Kim, Tae-Hee; Huang, Lihui; Chen, Xing; Feng, Chunping; Liu, Ling; Zhang, Li; Zhang, Wen; Zhou, Kun; Gan, Xiuni"

作者地址:"[Liu, Wei; Huang, Lihui; Chen, Xing; Feng, Chunping; Liu, Ling; Zhang, Li; Zhang, Wen; Zhou, Kun] Chongqing Med Univ, Affiliated Hosp 2, Clin Ctr Tumor Therapy, Chongqing, Peoples R China; [Kim, Tae-Hee] Seoul HIcare Clin, Seoul, South Korea; [Gan, Xiuni] Chongqing Med Univ, Affiliated Hosp 2, Nursing Dept, Chongqing, Peoples R China"

通信作者:"Zhou, K (通讯作者),Chongqing Med Univ, Affiliated Hosp 2, Clin Ctr Tumor Therapy, Chongqing, Peoples R China."

来源:INTERNATIONAL JOURNAL OF HYPERTHERMIA

ESI学科分类:CLINICAL MEDICINE

WOS号:WOS:001010183700001

JCR分区:Q2

影响因子:3

年份:2023

卷号:40

期号:1

开始页: 

结束页: 

文献类型:Article

关键词:Benign uterine disease; high-intensity focused ultrasound; intrarectal Foley catheter; feasibility analysis; safety

摘要:"Objective To evaluate the feasibility of using an intrarectal Foley catheter during ultrasound-guided high-intensity focused ultrasound (US-HIFU) in patients with benign uterine diseases of the posterior wall beyond the HIFU therapeutic range. Methods Patients were treated with US-HIFU and lesion changes were monitored using contrast-enhanced MRI from June 2020 to September 2021. A Foley catheter was inserted into the rectum to facilitate a successful US-HIFU ablation. Complications and lesion responses were recorded during the treatment and follow-up. Results Thirteen patients with 14 lesions beyond the device's treatable area were enrolled. The average placement time and insertion depth of the intrarectal Foley catheter was 7.6 +/- 2.7 min and 23.2 +/- 7.6 cm, respectively. A median of 50 mL degassed water was injected into the Foley catheter balloon. All 14 lesions were successfully pushed into a treatable area and subjected to HIFU. The average treatment time, irradiation time, and total therapeutic energy of HIFU were 44.2 +/- 17.3 min, 394.4 +/- 295.7 s, and 73.3 +/- 46.6 kJ, respectively. The mean non-perfusion volume (NPV) in all treated lesions was 23.2 +/- 19.2 cm3, and the mean NPV ratio was 57.8 +/- 16.9%. Major complications were not observed. Conclusion Intrarectal Foley catheter-assisted US-HIFU is effective and safe. Its clinical application could benefit patients with benign uterine diseases outside the HIFU therapeutic range."

基金机构:Kuanren Talents Program of the Second Affiliated Hospital of Chongqing Medical University [KY2019G019]; Future Medical Youth Innovation Team Support Program Project of Chongqing Medical University [2021 W0061]

基金资助正文:This work was supported by the Kuanren Talents Program of the Second Affiliated Hospital of Chongqing Medical University [No: KY2019G019] and The Future Medical Youth Innovation Team Support Program Project of Chongqing Medical University [No: 2021 W0061].