Effects of novel microimplant-assisted rapid palatal expanders manufactured by 3-dimensional printing technology: A finite element study
作者全名:"Pan, Shengyuan; Gao, Xiang; Sun, Jicheng; Yang, Zun; Hu, Bo; Song, Jinlin"
作者地址:"[Pan, Shengyuan; Gao, Xiang; Sun, Jicheng; Yang, Zun; Hu, Bo; Song, Jinlin] Chongqing Med Univ, Coll Stomatol, Chongqing, Peoples R China; [Pan, Shengyuan; Gao, Xiang; Sun, Jicheng; Yang, Zun; Hu, Bo; Song, Jinlin] Chongqing Key Lab Oral Dis & Biomed Sci, Chongqing, Peoples R China; [Pan, Shengyuan; Gao, Xiang; Sun, Jicheng; Yang, Zun; Hu, Bo; Song, Jinlin] Chongqing Municipal Key Lab Oral Biomed Engn Highe, Chongqing, Peoples R China; [Hu, Bo; Song, Jinlin] Chongqing Med Univ, Coll Stomatol, Chongqing 401147, Peoples R China"
通信作者:"Hu, B; Song, JL (通讯作者),Chongqing Med Univ, Coll Stomatol, Chongqing 401147, Peoples R China."
来源:AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS
ESI学科分类:CLINICAL MEDICINE
WOS号:WOS:001102633400001
JCR分区:Q1
影响因子:2.7
年份:2023
卷号:164
期号:5
开始页:700
结束页:711
文献类型:Article
关键词:
摘要:"Introduction: The expansion effects of several new microimplant-assisted rapid palatal expanders (MARPEs) manufactured by 3-dimensional printing technology were evaluated by finite element analysis (FEA). The aim was to identify a novel MARPE suitable for treating maxillary transverse deficiency. Methods: The finite element model was established using MIMICS software (version 19.0; Materialise, Leuven, Belgium). First, the appropriate microimplant insertion characteristics were identified via FEA, and several MARPEs with the above insertion patterns were manufactured by 3-dimensional printing technology. Then, the stress distribution and displacement prediction of the 4 MARPEs and hyrax expander (model E) were evaluated via FEA: bone -borne (model A), bone-tooth-borne (model B), bone-mucous-borne (model C), bone-tooth-mucous-borne (model D). Results: Monocortical microimplants perpendicular to the cortical bone on the coronal plane resulted in better expansion effects. Compared with a conventional hyrax expander, the orthopedic expansion of each of the 4 MARPEs was far larger, the parallelism was greater, and the posterior teeth tipping rate was lower. Among them, the expansion effects of models C and D were the best; the von Mises peak values on the surfaces of the microimplants were smaller than those of models A and B. Conclusions: This study may demonstrate that the 4 MARPEs obtained more advantageous orthopedic expansion effects than a hyrax expander. Models C and D obtained better biomechanical effects and had better primary stability. Overall, model D is the recommended expander for treating maxillary transverse deficiency because its structure acts like an implant guide and is beneficial for the accurate insertion of the microimplant. (Am J Orthod Dentofacial Orthop 2023;164:700-11)"
基金机构:2019 Chongqing Graduate Tutor Team Construction Project [dstd201903]; Chongqing Young and Middle-Aged Medical Excellence Team Project
基金资助正文:This work was supported by the 2019 Chongqing Graduate Tutor Team Construction Project (dstd201903) and Chongqing Young and Middle-Aged Medical Excellence Team Project.