Echocardiographic parameters predicting spontaneous closure of ductus arteriosus in preterm infants

作者全名:"He, Minyu; Yang, Zhengchun; Gan, Tian; Tang, Jing; Ran, Suzhen; Zhang, Kun"

作者地址:"[He, Minyu; Yang, Zhengchun; Gan, Tian; Tang, Jing; Ran, Suzhen; Zhang, Kun] Chongqing Hlth Ctr Women & Children, Dept Ultrasound, Chongqing, Peoples R China; [He, Minyu; Yang, Zhengchun; Gan, Tian; Tang, Jing; Ran, Suzhen; Zhang, Kun] Chongqing Med Univ, Dept Ultrasound, Women & Childrens Hosp, Chongqing, Peoples R China"

通信作者:"Yang, ZC (通讯作者),Chongqing Hlth Ctr Women & Children, Dept Ultrasound, Chongqing, Peoples R China.; Yang, ZC (通讯作者),Chongqing Med Univ, Dept Ultrasound, Women & Childrens Hosp, Chongqing, Peoples R China."

来源:FRONTIERS IN PEDIATRICS

ESI学科分类:CLINICAL MEDICINE

WOS号:WOS:001016221300001

JCR分区:Q2

影响因子:2.1

年份:2023

卷号:11

期号: 

开始页: 

结束页: 

文献类型:Article

关键词:patent ductus arteriosus; infant; premature; echocardiography; congenital heart disease

摘要:"ObjectiveTo evaluate the value of echocardiographic parameters in predicting early spontaneous closure of ductus arteriosus in premature infants. Methods222 premature infants admitted to the neonatal ward of our hospital were selected, and patent ductus arteriosus was detected by echocardiography 48 h after birth. On the 7th day, whether the ductus arteriosus was closed naturally in this cohort was observed. The infants whose ductus arteriosus were not closed were identified as the PDA group (n = 109), and the other infants were included in the control group (n = 113). The echocardiographic parameters of the two groups of premature infants at 48 h after birth were single-factor statistically and Pearson correlation analyzed, and the parameters with statistically significant differences in single-factor analyzed were selected for multivariate logistic stepwise regression analysis. ResultsThe ductus arteriosus shunt velocity and the pressure difference between the descending aorta and the pulmonary artery (& UDelta;Ps) in the PDA group were lower than those in the control group (P < 0.05). The pulmonary artery pressure (PASP) in the PDA group was higher than that in the control group (P < 0.05). According to the multivariate logistic stepwise regression analysis, only the maximum shunt velocity of ductus arteriosus was correlated with early spontaneous closure of ductus arteriosus in 48 h first echocardiographic parameters (P = 0.049). The receiver operating characteristic (ROC) curve indicates the optimal critical point of echocardiographic ductus arteriosus shunt velocity in premature infants 48 h after birth was 1.165 m/s. ConclusionEchocardiographic parameters are of great value in predicting the early spontaneous closure of ductus arteriosus in premature infants. In particular, the ductus arteriosus shunt velocity is correlated with the early spontaneous closure of ductus arteriosus."

基金机构: 

基金资助正文: