Immersion ultrasound improves the repeatability of shear-wave elastography for measuring median nerve elasticity
作者全名:"Zhang, Zhijun; Wang, Hui; Ding, Xiaoya; He, Shu"
作者地址:"[Zhang, Zhijun; Wang, Hui; Ding, Xiaoya] Chongqing Med Univ, Univ Town Hosp, Dept Ultrasound, Chongqing 401331, Peoples R China; [He, Shu] Fifth Peoples Hosp Chongqing, Med Affairs Dept, Chongqing 400030, Peoples R China"
通信作者:"He, S (通讯作者),Fifth Peoples Hosp Chongqing, Med Affairs Dept, Chongqing 400030, Peoples R China."
来源:JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH
ESI学科分类:CLINICAL MEDICINE
WOS号:WOS:001053700700002
JCR分区:Q1
影响因子:2.8
年份:2023
卷号:18
期号:1
开始页:
结束页:
文献类型:Article
关键词:Shear wave elastography; Median nerve; Repeatability
摘要:"ObjectiveTo study the factors that influence the measurement of median nerve elasticity, to provide a more reproducible test for the assessment of median nerve elasticity using shear wave elasticity (SWE), and to reduce operator empirical dependence. To compare the repeatability of the median nerve elasticity measurement using immersion SWE with that using contact SWE, analyze the factors affecting SWE measurement, and provide a more repeatable method for doctors without SWE operation experience.MethodsTwo doctors without SWE operation experience measured the median nerve mean elastic modulus (Emean) at the same position and at different time points on the right wrist of 58 healthy volunteers using immersion and contact ultrasound methods. The intraobserver and interobserver repeatability of measurements was assessed using the interclass correlation coefficient (ICC), while the repeatability was assessed using the Bland-Altman diagram.ResultsThe intraobserver and interobserver repeatability of the median nerve elasticity measured via contact SWE by inexperienced operators were classified as good, with ICCs of 0.633 (95% CI 0.380-0.783) and 0.552 (95% CI 0.243-0.735), respectively. The intraobserver and interobserver repeatability of the median nerve elasticity measured by immersion SWE were very good, with ICCs of 0.975 (95% CI 0.958-0.985) and 0.942 (95% CI 0.902-0.966), respectively. The intraobserver and interobserver Bland-Altman diagram of median nerve elasticity measured by immersion SWE showed that 98% of the points fell within the 95% limits of agreement. The intraobserver and interobserver Bland-Altman diagram of median nerve elasticity measured by contact SWE showed that 94% of the points fell within the 95% limits of agreement.ConclusionImmersion ultrasound can improve the repeatability of median nerve elasticity measurements by inexperienced operators."
基金机构:The authors thank all volunteers who participated in the study.
基金资助正文:The authors thank all volunteers who participated in the study.