The effect of gel pads on the measurement of breast superficial lesions by shear wave elastography
作者全名:"Zhang, Zhijun; He, Shu; Zhong, Yu; Zou, Hairong; Cai, Lu; Zhang, Yan; Wang, Hui"
作者地址:"[Zhang, Zhijun; Zhong, Yu; Zou, Hairong; Cai, Lu; Zhang, Yan; Wang, Hui] Chongqing Med Univ, Dept Ultrasound, Univ Town Hosp, Chongqing 401331, Peoples R China; [He, Shu] Fifth Peoples Hosp Chongqing, Med Affairs Dept, Chongqing, Peoples R China"
通信作者:"Wang, H (通讯作者),Chongqing Med Univ, Dept Ultrasound, Univ Town Hosp, Chongqing 401331, Peoples R China."
来源:ANNALS OF MEDICINE
ESI学科分类:CLINICAL MEDICINE
WOS号:WOS:001087634600001
JCR分区:Q1
影响因子:4.9
年份:2023
卷号:55
期号:2
开始页:
结束页:
文献类型:Article
关键词:Shear wave elastography; breast; coupling gel; gel pad; repeatability; ROC curve
摘要:"Objective This study aimed to compare the repeatability and diagnostic efficiency of shear wave elastography (SWE) while using coupling gel and gel pads in the diagnosis of superficial breast lesions.Methods Two experienced sonographers, trained in SWE, used different methods to perform the maximum Young's modulus (Emax) measurement of the lesion while using coupling gel SWE and gel pad SWE at different time points. All 80 lesions were in the superficial layer of the breast. The interclass correlation coefficient (ICC) was calculated to evaluate the intraobserver and interobserver repeatability. Meanwhile, the receiver operating characteristic curve (ROC curve) was used to calculate the sensitivity, specificity and area under the curve of the two methods.Results In the 80 breast lesions, the intraobserver and interobserver reproducibility of SWE measurements using coupling gel were considered good, and the ICCs were 0.728 (95% CI: 0.509-0.813) and 0.702 (95% CI: 0.492-0.795), respectively. The intraobserver and interobserver reproducibility of the SWE measured by the gel pad were also considered good, and the ICCs were 0.745 (95% CI: 0.501-0.801) and 0.713 (95% CI: 0.498-0.802), respectively. The sensitivity, specificity and area under the curve were 0.711 and 0.737, 0.929 and 0.905, and 0.873 and 0.878, respectively.Conclusions In the SWE measurement of superficial breast lesions, the use of a gel pad does not affect the repeatability and diagnostic efficiency of the measurement. The use of gel pads does not affect repeatability and diagnostic efficiency but also improves the near-field resolution of images. The gel pad has certain advantages in the observation of superficial lesions."
基金机构:The authors thank all volunteers who participated in the study.
基金资助正文:The authors thank all volunteers who participated in the study.