A novel rapid measurement method of cervical sagittal parameters based on the integrated inclinometer of a smartphone: a validity and reliability study

作者全名:"Huang, Tianji; Zhang, Chunyang; Han, Zhenghan; Zhong, Weiyang; Zhao, Zenghui; Zhu, Yong; Luo, Xiaoji; Zhang, Jie"

作者地址:"[Huang, Tianji; Han, Zhenghan; Zhong, Weiyang; Zhao, Zenghui; Zhu, Yong; Luo, Xiaoji] Chongqing Med Univ, Dept Orthoped Surg, Affiliated Hosp 1, Chongqing, Peoples R China; [Huang, Tianji; Han, Zhenghan; Zhong, Weiyang; Zhao, Zenghui; Zhu, Yong; Luo, Xiaoji] Chongqing Med Univ, Orthoped Lab, Chongqing, Peoples R China; [Zhang, Chunyang] Peoples Hosp Chongqing Banan Dist, Dept Orthoped Surg, Chongqing, Peoples R China; [Zhang, Jie] Chongqing Med Univ, Dept Oncol, Affiliated Hosp 1, Chongqing, Peoples R China; [Zhang, Jie] Chongqing Med Univ, Dept Oncol, First Affiliated Hosp, Chongqing 400016, Peoples R China"

通信作者:"Zhang, J (通讯作者),Chongqing Med Univ, Dept Oncol, First Affiliated Hosp, Chongqing 400016, Peoples R China."

来源:ANNALS OF MEDICINE

ESI学科分类:CLINICAL MEDICINE

WOS号:WOS:001117818700001

JCR分区:Q1

影响因子:4.9

年份:2023

卷号:55

期号:2

开始页: 

结束页: 

文献类型:Article

关键词:Smartphone; measurement; cobb angle; T1S; NT

摘要:"Objectives: A new method was introduced using a smartphone's integrated inclinometer for rapid measurement of sagittal cervical parameters. The present study aims to compare the validity and reliability of the proposed method.Methods: We retrospectively reviewed 120 patients with cervical spondylosis treated at our hospital. The C0-2 Cobb angle, C2-7 Cobb angle, T1-slope (T1S), and neck tilt (NT) were selected as representative sagittal angles for this study. Two methods, the smartphone's integrated inclinometer and picture archiving and communication system (PACS), were used to measure these four representative angles. Validity, reliability, and measurement times were recorded and compared.Results: The representative parameters (C0-2 Cobb angle, C2-7 Cobb angle, T1S, and NT), the ICC was 0.957 (0.939-0.970), 0.971 (0.958-0.979), 0.974 (0.963-0.982) and 0.949 (0.927-0.964) for validity respectively. For the aforementioned representative parameters, the ICC values were 0.972 (0.960-0.980), 0.979 (0.969-0.985), 0.972 (0.959-0.980), 0.942 (0.917-0.959) for intraobserver reliability respectively. For the representative parameters mentioned above, the ICC values were 0.947 (0.926-0.963), 0.964 (0.949-0.975), 0.956 (0.938-0.969), 0.916 (0.881-0.940) for interobserver reliability respectively. For the validity of the representative parameters mentioned above, the Bland-Altman plot displayed a mean difference of 0.2, 0.1, 0.1, and 0.4 degrees with a 95% CI of 4.3, 4.5, 3.4, and 4.1 degrees, respectively. The measurement by smartphone's integrated inclinometer (46.31 +/- 3.99 s) was significantly quicker than that by PACS (69.48 +/- 3.25 s) according to independent-samples T test (p < 0.001).Conclusion: This novel smartphone measurement based on the integrated inclinometer is accurate and reliable for measuring cervical sagittal parameters rapidly and conveniently."

基金机构:National Natural Science Foundation of China [81703083]; Higher Education Scientific Research Planning Project [22SZH0422]; Teaching Innovation Project of the First Affiliated Hospital of Chongqing Medical University [CMER202204]; Teaching Innovation Project of Chongqing Municipal Education Commission [233148]; Program for Youth Innovation in Future Medicine of Chongqing Medical University [W0086]

基金资助正文:"This study was funded by the National Natural Science Foundation of China (Grant No. 81703083), Higher Education Scientific Research Planning Project (22SZH0422), Teaching Innovation Project of the First Affiliated Hospital of Chongqing Medical University (CMER202204), Teaching Innovation Project of Chongqing Municipal Education Commission (233148) and Program for Youth Innovation in Future Medicine of Chongqing Medical University (Nos. W0086)."