Quantitative measurements at the lumbosacral junction are more reliable parameters for identifying and numbering lumbosacral transitional vertebrae

作者全名:"Zhou, Suying; Du, Lin; Liu, Xin; Wang, Qiqi; Zhao, Jie; Lv, Yuchan; Yang, Haitao"

作者地址:"[Zhou, Suying; Du, Lin; Liu, Xin; Wang, Qiqi; Zhao, Jie; Lv, Yuchan; Yang, Haitao] Chongqing Med Univ, Affiliated Hosp 1, Dept Radiol, 1 Youyi Rd, Chongqing 400016, Peoples R China"

通信作者:"Yang, HT (通讯作者),Chongqing Med Univ, Affiliated Hosp 1, Dept Radiol, 1 Youyi Rd, Chongqing 400016, Peoples R China."

来源:EUROPEAN RADIOLOGY

ESI学科分类:CLINICAL MEDICINE

WOS号:WOS:000766105900002

JCR分区:Q1

影响因子:5.9

年份:2022

卷号: 

期号: 

开始页: 

结束页: 

文献类型:Article; Early Access

关键词:Lumbosacral region; Lumbar vertebrae; Anatomic variation; Positron emission tomography/computed tomography

摘要:"Objectives To evaluate quantitative parameters to identify the anatomic variation lumbosacral transitional vertebrae (LSTV) and compare them with the landmarks commonly used at present. Methods A total of 2,845 PET/CT scans were reviewed, and the patients with 23 and 25 presacral vertebrae were included. The quantitative parameters, including the anterior-edge vertebral angle (AVA) of the lowest lumbar-type vertebra, the ratio of the length of the inferior endplate to that of the superior endplate (RISE) of the uppermost sacral-type vertebra and the lumbosacral intervertebral disc angle (LSIVDA), and the anatomical landmarks, including the iliac crest tangent (ICT) level, the iliolumbar ligament (ILL) origin level and psoas proximal insertion, were all evaluated to determine their ability to identify LSTV. Results The values of AVA and RISE were significantly different between the LSTV group and the control group, and between subgroups of LSTV. The cutoff value for AVA was 73.0 degrees, with an accuracy, sensitivity, and specificity of 91.1%, 77.5%, and 88.3%, and that for RISE was 0.79, with an accuracy, sensitivity, and specificity of 90.3%, 77.5%, and 94.2%, while that for LSIVDA was 14.15 degrees, with an accuracy, sensitivity, and specificity of 75.9%, 65.7%, and 78.3%, to differentiate L5 sacralization from S1 lumbarization. For differentiating the controls from LSTV, the accuracy, sensitivity, and specificity of the ICT level and proximal psoas insertion were 78.0%, 70.2%, and 95.0%, versus 71.7%, 61.7%, and 94.0%. Conclusions Compared with the anatomical landmarks, the quantitative measurements at the lumbosacral junction, including AVA and RISE, may be more helpful for differentiating subgroups of LSTV especially if only lumbar spine imaging is available."

基金机构: 

基金资助正文: