Reliability of different smartphones measuring the hallux valgus parameters in a new rapid method: a follow-up study

作者全名:"Wang, Lin; Zhang, Chao; Liang, Hao; Zhang, Jun; Zhong, Weiyang; Zhao, Zenghui; Huang, Tianji; Luo, Xiaoji"

作者地址:"[Wang, Lin; Zhang, Chao; Liang, Hao; Zhang, Jun; Zhong, Weiyang; Zhao, Zenghui; Huang, Tianji; Luo, Xiaoji] Chongqing Med Univ, Affiliated Hosp 1, Dept Orthoped Surg, Chongqing 400016, Peoples R China; [Wang, Lin; Zhang, Chao; Liang, Hao; Zhang, Jun; Zhong, Weiyang; Zhao, Zenghui; Huang, Tianji; Luo, Xiaoji] Chongqing Med Univ, Orthoped Lab, Chongqing 400016, Peoples R China"

通信作者:"Huang, TJ (通讯作者),Chongqing Med Univ, Affiliated Hosp 1, Dept Orthoped Surg, Chongqing 400016, Peoples R China.; Huang, TJ (通讯作者),Chongqing Med Univ, Orthoped Lab, Chongqing 400016, Peoples R China."

来源:BMC MUSCULOSKELETAL DISORDERS

ESI学科分类:CLINICAL MEDICINE

WOS号:WOS:000777400200002

JCR分区:Q2

影响因子:2.3

年份:2022

卷号:23

期号:1

开始页: 

结束页: 

文献类型:Article

关键词:Hallux valgus; Smartphones; Measurement; HVA; IMA

摘要:"Objective This study aimed to further compare the abilities to measure hallux valgus parameters in different smartphones using the intrinsic photograph-editing function. Methods We retrospectively reviewed 61 patients (100 feet) of hallux valgus without medical or surgical interventions at our department. The radiographic parameters were assessed and measured via the Picture archiving and communication systems (PACS), iPhone, and Android. The accuracy, reliability, and the time-taken were compared and analyzed between each two methods. Results The mean value of measured hallux valgus parameters were as follow: hallux valgus angle (HVA): 33.71 +/- 7.25 degrees; the first and second intermetatarsal angle (IMA): 12.84 +/- 3.62 degrees in PACS; HVA: 33.59 +/- 7.18 degrees and IMA: 12.80 +/- 3.65 degrees in Android; HVA: 33.63 +/- 7.23 degrees and IMA: 12.87 +/- 3.60 degrees in iPhone. No significant difference was found among the average results measured by PACS, Android and iPhone (F = 0.008, P = 0.992 in HVA; F = 0.009, P = 0.991 in IMA). For measurements by PACS, Android smartphone, and iPhone, the variability of HVA (F = 0.061, P = 1.000) and IMA (F = 0.133, P = 1.000) was similar. The intraclass correlation coefficients (ICCs) of the mean results of four times measurements of HVA and IMA as follows: PACS vs Android: 0.995 (0.993-0.997) and 0.982 (0.973-0.988); PACS vs iPhone:0.997 (0.995-0.998) and 0.974 (0.962-0.982); Android vs iPhone:0.997 (0.995-0.998) and 0.981 (0.971-0.987). The interobserver and intraobserver reliability was very good for Android smartphones and iPhone in measuring hallux valgus parameters. The mean time of measurement by PACS, Android smartphone, and iPhone were 25.34 +/- 1.18 s, 20.10 +/- 0.92 s, and 19.92 +/- 0.99 s respectively. The measurement time of smartphones is significantly faster than that of PACS by about 5 seconds (P = 0.000). The measurement time of iPhone was slightly faster than that of Android smartphone, while no significant difference was found (P = 0.24). Conclusion It is more convenient and faster to use smartphones when compared with PACS, at the same level of accuracy. Furthermore, the abilities of different smartphone platforms are proven to be of no significant difference."

基金机构:National Natural Science Foundation of China [81873998]; Natural Science Foundation of Chongqing [cstc2017jcyjAX0039]; Medical Scientific Research Cultivating Foundation of The First Affiliated Hospital of Chongqing Medical University [PYJJ2019-227]

基金资助正文:"This study was funded by the National Natural Science Foundation of China (81873998), Natural Science Foundation of Chongqing (cstc2017jcyjAX0039) and Medical Scientific Research Cultivating Foundation of The First Affiliated Hospital of Chongqing Medical University (PYJJ2019-227)."